10kW 96V Single-Phase Low-Frequency Off-Grid Solar Inverter Charger
A 10 kW single-phase low-frequency off-grid solar inverter charger designed for compatible 96 V battery systems. The MPPT-equipped configuration combines pure sine wave AC output, utility charging, high-voltage solar charging, low-frequency transformer isolation and RS232/RS485 communication for residential, commercial and remote-power applications.
Share to:
1. Integrated Off-Grid Inverter Charger
This 10 kW single-phase low-frequency inverter charger combines pure sine wave power conversion, utility charging and MPPT solar charging in one cabinet system. The MPPT-equipped configuration is designed for compatible off-grid, standalone solar and backup-power systems using a 96 V DC battery bank.
2. 10 kW Pure Sine Wave Output
• 10 kW Rated Power: Supplies compatible residential, commercial and industrial loads within the inverter’s rated capacity.
• 220 V AC Output: Provides regulated 220 V AC output with ±5% voltage tolerance.
• 50/60 Hz Operation: Supports compatible 50 Hz and 60 Hz electrical systems.
• Pure Sine Wave Supply: Provides pure sine wave output with total harmonic distortion below 3% at full load.
• Low-Frequency Transformer: Uses an industrial-frequency isolation transformer for high-power conversion and electrical isolation.
• Fast Transfer: Provides a transfer time of less than 10 ms between available power sources.
• Inverter Efficiency: The supplier specifies inverter efficiency above 85%.
3. 96 V Battery System
• 96 V DC Battery Platform: Designed for a compatible 96 V battery bank.
• Lead-Acid and Lithium Battery Support: Can be configured for compatible lead-acid or lithium batteries when the charging settings are correctly matched.
• 84 V Over-Discharge Protection: Helps protect the connected battery bank against excessive discharge.
• Battery Management: Supports constant-voltage charging and configurable charging settings for the selected battery system.
• Battery-System Selection: Battery chemistry, capacity, charge voltage, current limits and any required communication functions must be confirmed before installation.
4. Utility Input and Charging
• Single-Phase AC Input: Accepts compatible 220/230 V AC input with ±15% voltage tolerance.
• 50/60 Hz Input: Supports AC input frequency of 50 or 60 Hz with ±5% tolerance.
• Adjustable Utility Charging: The technical table specifies selectable utility-charging current from 0 to 70 A maximum.
• Generator Compatibility: Can be connected to a compatible generator for off-grid sites or locations with an unstable utility supply.
• Selectable Operating Modes: Supports different operating priorities for compatible utility, battery and solar configurations.
5. MPPT Solar Charging
• Single MPPT Input: Provides one photovoltaic input channel for the 96 V configuration.
• 120-300 V DC PV Input Range: Supports a compatible high-voltage photovoltaic array within the specified voltage range.
• 210 V DC Recommended PV Voltage: Provides a reference operating voltage for PV array configuration.
• 300 V DC Maximum PV Input: The array open-circuit voltage must remain below this limit under all operating and temperature conditions.
• 120 V DC Controller Overvoltage Threshold: Provides the stated overvoltage-protection value for the 96 V configuration.
• High MPPT Efficiency: The supplier specifies MPPT tracking efficiency above 99.5%.
• Configuration-Based Charging Current: The catalog lists 100 A and 200 A maximum solar-charging configurations; the standard current for the selected unit must be confirmed before ordering.
6. Protection and Monitoring
• Output Short-Circuit Protection: Responds to an output short-circuit condition.
• Overvoltage and Undervoltage Protection: Protects the system against abnormal output-voltage conditions.
• Low-Battery Protection: Helps prevent operation below the configured battery-voltage limit.
• Overload Management: Provides alarm, bypass transfer or shutdown according to the overload level and bypass configuration.
• Automatic Self-Test: Checks selected system conditions during startup.
• System Display: Provides access to operating status and system parameters.
• RS232/RS485 Communication: Supports compatible remote monitoring and power-system management.
• Automatic Recovery: Supports recovery from selected fault conditions after the cause has been cleared.
7. B2B System Applications
The inverter charger is suitable for off-grid system integrators, solar-equipment distributors, backup-power contractors and energy-system suppliers. Typical applications include homes, schools, public-lighting systems, farms, islands, remote facilities and industrial sites requiring a high-capacity single-phase AC supply.
PV array design, battery configuration, AC input conditions, load characteristics, cable size, protective devices and destination-market requirements must be confirmed before installation.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Type | Low-frequency off-grid solar inverter charger |
| Product Configuration | MPPT-equipped configuration |
| Rated Output Power | 10 kW |
| Phase Configuration | Single phase with ground |
| Inverter Topology | Low-frequency transformer-based inverter |
| Battery Type | Compatible lead-acid or lithium battery |
| Rated Battery Voltage | 96 V DC |
| Battery Over-Discharge Protection | 84 V DC |
| AC Input Voltage | 220/230 V AC ±15% |
| AC Input Frequency | 50/60 Hz ±5% |
| Utility Charging Current | 0-70 A maximum, selectable according to the technical table |
| MPPT Input Quantity | 1 for the 96 V configuration |
| PV Input Voltage Range | 120-300 V DC |
| Recommended PV Operating Voltage | 210 V DC |
| Maximum PV Input Voltage | 300 V DC |
| Maximum Solar-Charging Current | 100 A / 200 A, depending on controller configuration |
| Controller Overvoltage Protection Threshold | 120 V DC |
| MPPT Efficiency | >99.5% |
| Rated AC Output Voltage | 220 V AC ±5% |
| Output Frequency | 50/60 Hz |
| Output Waveform | Pure sine wave |
| Total Harmonic Distortion | <3% at full load |
| Inverter Efficiency | >85% |
| Transfer Time | <10 ms |
| Isolation Method | Low-frequency isolation transformer |
| Output Protection | Short-circuit, overvoltage, undervoltage and low-battery protection |
| Communication Interfaces | RS232 and RS485 |
| Storage Temperature | -40°C to +70°C |
| Relative Humidity | 0-90%, non-condensing |
| Product Dimensions | 650 × 570 × 1270 mm |
| Net Weight | 140 kg |
| Package Dimensions | 800 × 710 × 1440 mm |
| Gross Weight | 165 kg |
Overload Performance
With Bypass
• Above 100% load: An alarm is activated, followed by transfer to bypass mode after 1 minute.
• Above 125% load: Immediate transfer to bypass mode.
Without Bypass
• Above 100% load: An alarm is activated, followed by shutdown after 1 minute.
• Above 125% load: Immediate shutdown.
Applications
• Residential off-grid power systems
• Home and building backup power
• Schools and public facilities
• Public-lighting systems
• Farms and remote agricultural sites
• Islands and remote properties
• Border and field facilities
• Industrial equipment and workshops
• Generator-assisted off-grid systems
• Solar and battery system-integration projects
Package
Standard Package
• Off-grid solar inverter charger: 1 unit
Packaging Information
• Product dimensions: 650 × 570 × 1270 mm
• Package dimensions: 800 × 710 × 1440 mm
• Net weight: 140 kg
• Gross weight: 165 kg
Included cables, communication accessories, manuals and external protective devices should be confirmed according to the final order configuration.